Synchronous Motor Archives - Electrical and Electronics Blog https://howelectrical.com/tag/synchronous-motor/ Power System, Power electronics, Switch Gear & Protection, Electric Traction, Electrical Machine, Control System, Electrical Instruments & Measurement. Sat, 22 Apr 2023 08:32:36 +0000 en-US hourly 1 https://wordpress.org/?v=6.6.2 https://i0.wp.com/howelectrical.com/wp-content/uploads/2022/10/cropped-cropped-how-electrical-logo.png?fit=32%2C32&ssl=1 Synchronous Motor Archives - Electrical and Electronics Blog https://howelectrical.com/tag/synchronous-motor/ 32 32 What is Distribution Factor? Definition, Derivation & Formula https://howelectrical.com/distribution-factor/ https://howelectrical.com/distribution-factor/#respond Fri, 21 Apr 2023 13:56:56 +0000 https://howelectrical.com/?p=1117 The ratio of the phasor sum of E.M.Fs induced in all the coils distributed in a number of slots under one pole to the arithmetic sum of the E.M.Fs induced is known as distribution factor (Kd). It is also known as breadth factor (Kb). Distribution factor, Kd =EMF induced in distributed winding / EMF induced […]

The post What is Distribution Factor? Definition, Derivation & Formula appeared first on Electrical and Electronics Blog.

]]>
The ratio of the phasor sum of E.M.Fs induced in all the coils distributed in a number of slots under one pole to the arithmetic sum of the E.M.Fs induced is known as distribution factor (Kd). It is also known as breadth factor (Kb).

Distribution factor,

Kd =EMF induced in distributed winding / EMF induced if the winding would have been concentrated

\[=\frac{\text{Phasor sum of E}\text{.M}\text{.F components}}{\text{Arithmetic sum of E}\text{.M}\text{.F components}}\]

The distribution factor is always less than unity.

Derivation for Distribution Factor

What is Distribution Factor

Figure 1.

Let,

Number of slots/pole/phase = m

Number of slots/pole = n

E.M.F induced in each coil side = Ec

Angular displacement between the slots = β

Where,

\[\beta =\frac{180{}^\circ }{n}\]

Phase spread angle = mβ in radians or electrical degrees.

The E.M.F induced in different coils of one phase under one pole are represented by AB, BC and CD. They are equal in magnitude and differ in phase by each other and are shown in figure (1).

E.M.Fs induced in each coil side are equal in magnitude = Ec = E.

\[E=AB\times 2\times OA\times \sin \frac{\beta }{2}\]

\[\text{Arithmetic sum = }m\times 2\times OA\times \sin \frac{\beta }{2}\]

ER = The resultant E.M.F induced in one polar group of one phase and is represented by the phasor AF in figure (1)

The resultant E.M.F will be,

\[{{E}_{R}}=OF\]

\[=2\times OA\times \sin \frac{AOF}{2}\]

\[=2\times OA\times \sin \frac{m\beta }{2}\]

Now, distribution factor (Kd) is given by,

Phasor sum of E.M.F components

\[{{K}_{d}}=\frac{\text{Phasor sum E}\text{.M}\text{.F components}}{\text{Arithmetic sum E}\text{.M}\text{.F components}}\]

\[{{K}_{d}}=\frac{2\times OA\times \sin \frac{m\beta }{2}}{2\times OA\times \sin \frac{AOF}{2}}\]

\[{{K}_{d}}=\frac{\sin \frac{m\beta }{2}}{m\sin \frac{\beta }{2}}\]

This equation is for fundamental component of E.M.F.

If flux distribution contains space harmonics, the slot angular pitch β would be ‘rβ’ for the rth harmonic component, then distribution factor for rth harmonic component,

\[{{K}_{dr}}=\frac{\sin r\frac{m\beta }{2}}{m\sin \frac{r\beta }{2}}\]

Distribution factor reduces the number of conductors per slot thereby, temperature rise at centre of slot also reduces.

The post What is Distribution Factor? Definition, Derivation & Formula appeared first on Electrical and Electronics Blog.

]]>
https://howelectrical.com/distribution-factor/feed/ 0
Synchronous Motor Starting Methods https://howelectrical.com/synchronous-motor-starting-methods/ https://howelectrical.com/synchronous-motor-starting-methods/#respond Mon, 14 Feb 2022 22:03:12 +0000 https://howelectrical.com/?p=7 Synchronous Motor needs initial starting torque. For this purpose different methods can be used. Methods Use of damper winding Use of pony-motor Use of small induction motor Starting as slip-ring induction motor. Using Damper Winding In rotor pole shoe part, copper bars are put These copper bars are shorted at both ends by means of end […]

The post Synchronous Motor Starting Methods appeared first on Electrical and Electronics Blog.

]]>
Synchronous Motor needs initial starting torque. For this purpose different methods can be used.

Methods

  1. Use of damper winding
  2. Use of pony-motor
  3. Use of small induction motor
  4. Starting as slip-ring induction motor.

Using Damper Winding

In rotor pole shoe part, copper bars are put These copper bars are shorted at both ends by means of end ring. The construction of rotor is similar to induction motor’s rotor (squirrel cage type). So this motor can now start as an induction motor. The induction motor is self start motor.

Synchronous Motor Starting Methods

Fig. 1: Damper winding location

The rotor now, runs at a speed slightly less than synchronous speed (i.e. stator moving field). And then magnetic locking takes place automatically and motor now runs as a synchronous motor.

Damper winding e.m.f

The speed of stator rotating magnetic field is N and that of rotor is N. At start, the rotor speed N = 0 since rotor is at rest So relative speed is (Ns – N) = Ns. The damper winding cuts the rotating magnetic field of stator and due to electromagnetic induction an e.m.f is induced in it. This e.m.f is proportional to (Ns – N). The relative speed (Ns – N) is maximum at start so e.m.f in damper winding will be maximum. As the motor gathers speed, N increases and relative speed (Ns – N) decreases. The damper winding e.m.f will also decrease under running condition.

Using Pony Motor

Pony motor is a small DC shunt motor. It is mechanically coupled to rotor of synchronous motor. The pony motor rotates the rotor at synchronous speed. The magnetic locking takes place and motor now runs as a synchronous motor. After this, the pony motor’s DC supply is made OFF so pony motor will not play any role in running condition k is used just for the sake of starting the synchronous motor.

Synchronous Motor Starting Methods

Fig. 2: Using pony motor

Using Small Induction Motor

Arrangement is similar to previous method. An induction motor is used (squirrel cage type) to give initial rotation. Once the speed is developed and poles are magnetically coupled, the induction motor is mechanically de-coupled and motor runs as synchronous motor at a constant speed (Ns = 120.f / P ) (See Fig. 3).

Synchronous Motor Starting Methods

Fig. 3 : Use of small induction motor

Starting it as Slip-Ring Induction Motor

The synchronous motor is made to start as an slip-ring induction motor. The rotor winding needs some modification. 3 phase supply is connected to rotor by means of change over switch. The motor starts as an induction motor. It runs near synchronous speed, then DC supply is connected, now it runs as a synchronous motor. This method is not used in practice because of complications in field winding. The damper winding method is most popular for starting of synchronous motor.

methods of Synchronous Motor Starting

Fig. 4 : Starting it as slip-ring induction motor.

The post Synchronous Motor Starting Methods appeared first on Electrical and Electronics Blog.

]]>